Datacenter Battery (Nickel-Zinc) Source Factory & Best Deal

Gerchamp’s nickel-zinc data center batteries deliver 3C high-rate discharge performance, providing highly reliable backup power while reducing the physical footprint by 50%.

Datacenter Battery (Nickel-Zinc)

Data Center Design Engineers:

Seeking compact, high-energy-density storage that complies with stringent fire safety standards to optimize floor plans.

Datacenter Battery(Nickel-Zinc)  Expand applications

IDC Operations & Maintenance (O&M):

Focused on reducing battery replacement frequency and ensuring system readiness with low-maintenance, non-explosive backup power.

Datacenter Battery(Nickel-Zinc)  Expand applications

IT Directors (Finance/Banking):

Requiring strong high-rate discharge capabilities for seamless power transition during utility fluctuations.

Datacenter Battery(Nickel-Zinc)  Expand applications

Energy Solution Architects:

Focused on green data centers and reducing cooling energy consumption through wide-temperature battery technology.

Datacenter Battery(Nickel-Zinc)  Expand applications
Datacenter Battery (Nickel-Zinc)(images 6)

High-Rate, High-Current Discharge:

Supports 3C continuous discharge, enabling the release of extremely high power within a short period. This perfectly matches the instantaneous high-load requirements of data-center UPS systems, ensuring zero-delay power switchover.

Datacenter Battery (Nickel-Zinc)(images 7)

Ultimate Thermal Stability and Safety:

Verified by UL 9540A testing, the battery chemistry is inherently stable. It exhibits no risk of fire or explosion under extreme conditions (such as nail penetration or short circuits), fundamentally addressing fire safety concerns without the need for complex monitoring systems.

Datacenter Battery (Nickel-Zinc)(images 8)

Wide Temperature Adaptability:

Operates reliably from -20°C to 55°C. This high-temperature tolerance reduces the data center’s reliance on precision air conditioning, effectively optimizing the PUE (Power Usage Effectiveness) index.

Datacenter Battery (Nickel-Zinc)(images 9)

High Volumetric Energy Density:

With a volumetric energy density of 137.4 Wh/L, it is significantly more compact than traditional lead-acid batteries, releasing valuable rack space and increasing power density per unit area.

Datacenter Battery (Nickel-Zinc)(images 10)

Long-Term Service Life:

Features a cycle life of 300+ cycles (at 3C, 100% DOD). Its low self-discharge rate ensures the battery retains over 70% of its charge after 12 months of storage, significantly reducing long-term replacement costs.

Datacenter Battery (Nickel-Zinc)(images 11)

Eco-Friendly Material System:

Utilizing a nickel-zinc chemical structure, the battery contains no lead, cadmium, or other toxic heavy metals. It fully complies with RoHS and the latest EU battery regulations, simplifying the recycling process.

Parameter ItemsTechnical Specifications
Product Model8XNFZ38
Nominal Voltage13.2V
Nominal Capacity38Ah (1C discharge to 10.4V)
Nominal Power920W (30-minute rate)
Max Discharge Current114A (3C)
Internal Resistance< 8mΩ
Weight7.8kg (±200g)
Mass Energy Density67.7 Wh/kg
Volumetric Energy Density137.4 Wh/L
Float Charge Voltage14.80V
Cycle Life300 cycles (3C, 100% DOD)
Casing Flame RatingV0 Flame-retardant ABS
Operating Temperature-20°C to 55°C
Dimensions (L×W×H)225.5 × 122.5 × 142.5 mm

Nickel-zinc batteries represent a transformative shift for data center infrastructure, balancing high power density with a safety profile that exceeds both lead-acid and lithium-ion standards. By focusing on the intrinsic chemistry of the battery hardware, this solution provides a robust, low-maintenance power reserve that directly addresses the spatial and thermal challenges of modern high-density server environments.

Datacenter Battery(Nickel-Zinc)

Datacenter Battery (Nickel-Zinc)(images 13)

30-50% Weight Reduction vs. Lead-Acid:

Under identical power output conditions, Ni-Zn batteries significantly reduce the physical load on data center floors, allowing for full cabinet installations in multi-story facilities where floor loading is a constraint.

Datacenter Battery (Nickel-Zinc)(images 14)

Intrinsic Fire Safety vs. Lithium-ion:

Unlike lithium-ion alternatives, Ni-Zn’s aqueous electrolyte is non-flammable, naturally preventing the chain reaction of thermal runaway even under mechanical stress or electrical failure.
Datacenter Battery (Nickel-Zinc)(images 15)

2 – 4 Times Backup Capacity Increase:

The high volumetric energy density allows for a 2 – 4 times increase in power reserves within the same rack footprint, maximizing revenue-generating space while maintaining superior high-rate discharge performance.
Q: What are the safety advantages of Ni-Zn over Lithium batteries?
A: Ni-Zn batteries use an aqueous electrolyte, which is intrinsically safe. They do not suffer from thermal runaway and will not catch fire or explode under overcharge or physical damage.
Q: Does the battery support fast charging?
A: Yes, it supports 1C rate charging, allowing the battery to recover most of its capacity in about one hour.
Q: Are there special installation requirements?
A: No. The fully sealed, V0-rated design allows for multi-angle installation in compact cabinets without risk of leakage.
Q: What is the discharge performance after long-term storage?
A: The self-discharge rate is extremely low; after 12 months of maintaining 80% power, it still maintains 70% power.
Q: Is this battery compliant with European export standards?
A: Yes, it is fully RoHS certified and meets the latest EU battery regulations, containing no lead or mercury.
/
/
E-mail*
Number
Country
Name
Your Question
Submitting!
Success!
Submission failed! Please try again later!
Email format error!
Format error!

Datacenter Battery (Nickel-Zinc) Source Factory & Best Deal

Gerchamp’s nickel-zinc data center batteries deliver 3C high-rate discharge performance, providing highly reliable backup power while reducing the physical footprint by 50%.

Industrial Battery Backup Systems (Gerchamp Nickel Zinc battery)

Datacenter Battery (Nickel-Zinc)(images 17)

Supports 3C continuous discharge, enabling the release of extremely high power within a short period. This perfectly matches the instantaneous high-load requirements of data-center UPS systems, ensuring zero-delay power switchover.

Datacenter Battery (Nickel-Zinc)(images 18)

Verified by UL 9540A testing, the battery chemistry is inherently stable. It exhibits no risk of fire or explosion under extreme conditions (such as nail penetration or short circuits), fundamentally addressing fire safety concerns without the need for complex monitoring systems.

Datacenter Battery (Nickel-Zinc)(images 19)

Operates reliably from -20°C to 55°C. This high-temperature tolerance reduces the data center’s reliance on precision air conditioning, effectively optimizing the PUE (Power Usage Effectiveness) index.

Datacenter Battery (Nickel-Zinc)(images 20)

With a volumetric energy density of 137.4 Wh/L, it is significantly more compact than traditional lead-acid batteries, releasing valuable rack space and increasing power density per unit area.

Datacenter Battery (Nickel-Zinc)(images 21)

Features a cycle life of 300+ cycles (at 3C, 100% DOD). Its low self-discharge rate ensures the battery retains over 70% of its charge after 12 months of storage, significantly reducing long-term replacement costs.

Datacenter Battery (Nickel-Zinc)(images 22)

Utilizing a nickel-zinc chemical structure, the battery contains no lead, cadmium, or other toxic heavy metals. It fully complies with RoHS and the latest EU battery regulations, simplifying the recycling process.

Parameter ItemsTechnical Specifications
Product Model8XNFZ38
Nominal Voltage13.2V
Nominal Capacity38Ah (1C discharge to 10.4V)
Nominal Power920W (30-minute rate)
Max Discharge Current114A (3C)
Internal Resistance< 8mΩ
Weight7.8kg (±200g)
Mass Energy Density67.7 Wh/kg
Volumetric Energy Density137.4 Wh/L
Float Charge Voltage14.80V
Cycle Life300 cycles (3C, 100% DOD)
Casing Flame RatingV0 Flame-retardant ABS
Operating Temperature-20°C to 55°C
Dimensions (L×W×H)225.5 × 122.5 × 142.5 mm

Industrial Battery Backup Systems (Gerchamp Nickel Zinc battery)

Datacenter Battery (Nickel-Zinc)(images 24)
Under identical power output conditions, Ni-Zn batteries significantly reduce the physical load on data center floors, allowing for full cabinet installations in multi-story facilities where floor loading is a constraint.
Datacenter Battery (Nickel-Zinc)(images 25)
Unlike lithium-ion alternatives, Ni-Zn’s aqueous electrolyte is non-flammable, naturally preventing the chain reaction of thermal runaway even under mechanical stress or electrical failure.
Datacenter Battery (Nickel-Zinc)(images 26)
The high volumetric energy density allows for a 2 – 4 times increase in power reserves within the same rack footprint, maximizing revenue-generating space while maintaining superior high-rate discharge performance.

Data Center Design Engineers:

Seeking compact, high-energy-density storage that complies with stringent fire safety standards to optimize floor plans.

Datacenter Battery(Nickel-Zinc)  Expand applications

IDC Operations & Maintenance (O&M):

Focused on reducing battery replacement frequency and ensuring system readiness with low-maintenance, non-explosive backup power.

Datacenter Battery(Nickel-Zinc)  Expand applications

IT Directors (Finance/Banking):

Requiring strong high-rate discharge capabilities for seamless power transition during utility fluctuations.

Datacenter Battery(Nickel-Zinc)  Expand applications

Energy Solution Architects:

Focused on green data centers and reducing cooling energy consumption through wide-temperature battery technology.

Datacenter Battery(Nickel-Zinc)  Expand applications
Q: What are the safety advantages of Ni-Zn over Lithium batteries?
A: Ni-Zn batteries use an aqueous electrolyte, which is intrinsically safe. They do not suffer from thermal runaway and will not catch fire or explode under overcharge or physical damage.
Q: Does the battery support fast charging?
A: Yes, it supports 1C rate charging, allowing the battery to recover most of its capacity in about one hour.
Q: Are there special installation requirements?
A: No. The fully sealed, V0-rated design allows for multi-angle installation in compact cabinets without risk of leakage.
Q: What is the discharge performance after long-term storage?
A: The self-discharge rate is extremely low; after 12 months of maintaining 80% power, it still maintains 70% power.
Q: Is this battery compliant with European export standards?
A: Yes, it is fully RoHS certified and meets the latest EU battery regulations, containing no lead or mercury.
/
/
*