Modular Data Center for AI Era

The Core Idea — Building Blocks, Not Boxes

AI Infrastructure That Expands Like Lego Blocks

A modular data center is a ready-made computing block that expands as your AI cluster grows. You add capacity the way you snap together Lego bricks, start with what you need, then scale block by block.

Every block is a factory-built, liquid-cooled AI infrastructure module — power, cooling, controls, and monitoring integrated and pre-tested before it ships. We engineer in flexible, pre-planned space for OCP or NVL72 rack systems, so your chosen compute drops in and goes live without rework.

This matters because the AI era’s real bottleneck is no longer chips alone, it is power, cooling, and deployment speed.

Why This Modular Approach

  • Factory prefabrication, BIM-engineered. BIM digital design and lean off-site fabrication build pipework, electrical, and cooling as integrated systems — higher quality, less on-site welding, lower risk, faster delivery.
  • Integrated by design. Each block combines server racks, power distribution, cable management, fire protection, and precision cooling into one standardized enclosure. You get a tested system, not a parts list.
  • Resilient power. UPS + Nickel-Zinc BBU + BMS protect workloads and simplify battery management.
  • Operations visibility from day one. DCIM monitors power, liquid cooling, environment, and security with real-time alarms, PUE analytics, asset lifecycle, and capacity planning.
  • Energy-near friendly. Small enough to deploy behind-the-meter, at renewable sites, or on stranded/underutilized power — turning idle energy into AI capacity.
Gerchamp 500kW All-in-One Modular AIDC

Why this modular approach

Core Technologies. Engineered in-house.

Our in-house liquid cooling is built for high-density GPU racks (OCP, NVIDIA GB200/300/Rubin), with direct-to-chip loops and closed-circuit design. Our in-house power — UPS + BBU + BMS with nickel-zinc battery cabinets — delivers resilient backup. BIM-engineered prefabrication cuts on-site welding and speeds delivery. DCIM gives you operations visibility from day one, and the block is energy-near friendly — deployable behind-the-meter or at stranded power.

Architecture: IT Zone + Power Zone + Liquid Cooling Zone + DCIM

One Platform · Two Building Blocks

Pick the block that fits your site

Two modular system, one engineering philosophy. Choose by speed, capacity, and how much you want to customize.

Faster · Standardized

500kW All-in-One Modular-Containerized AIDC

A factory-integrated unit you deploy quickly and repeat. Add units to grow toward any size.

  • Turnkey
  • Ready to connect
  • Standardized
  • Behind-the-meter
  • Pre-integrated enclosure, electrical & cooling, ships as tested block.
  • Flexible, pre-planned space for OCP and NVL72 / GPU-accelerator racks.
  • Direct-to-chip (DTC) liquid cooling for high-density racks.
  • UPS + Nickel-Zinc BBU + BMS for resilient backup power.
  • On-grid/off-grid

SCALABLE · CUSTOM

3.5MW KIT Modular-Containerized AIDC

A configurable modular system for higher-density training, large inference, HPC, and cloud-scale compute.

  • On-site assemble
  • Configured to site
  • High-density
  • Cluster-scale
  • Modular power & cooling sized to your load profile
  • Rack-level density tailored per aisle for your GPU platform
  • Liquid cooling designed around your chosen racks
  • UPS + Nickel-Zinc BBU + BMS for resilient backup power.
  • On-grid/off-grid

Gerchamp Modular Data Center Solutions

FAQs

Discover Frequent Asked Questions of Modular Data Center

What is a modular or prefabricated data center?

A factory-built computing block that integrates IT zone, power zone, cooling systems, and management into one enclosure, then ships to site for fast connection and commissioning, and expands like Lego blocks as capacity grows.

Modular data center vs traditional build — which is better?

For AI and compute workloads, modular wins on time and certainty. Traditional builds take 2–5 years from land to load; prefabricated blocks deploy in months after site readiness, with quality locked in at the factory. Choose modular when speed, power, and scalability matter more than a one-off custom building.

Do I need to supply my own servers and GPUs?

Yes. We design and engineer the powered-and-cooled infrastructure — enclosure, liquid cooling, power, controls, and monitoring. IT zone were reserved for your chosen rack systems. You bring the compute; it plugs in and goes live.

What liquid cooling technology do you use in your modular data centers?

We use self-developed closed-loop direct-to-chip (DTC) liquid cooling solution with Gerchamp’s Bluearth liquid cooling technology for high-density AI and accelerator racks, including OCP racks and NVIDIA GB200/300/Rubin systems at 120kW+ per rack.

What type of batteries and backup power do your modular data centers use?

Each block pairs with Gerchamp backup solution with self-developed UPS, nickel-zinc battery based BBU and battery monitoring system. Clients can bring their own diesel gensets, gas turbine, renewable energy with our modular data center.

Is your modular data center system self-developed?

Our core technologies are developed in-house, the liquid cooling solution, the power/backup architecture, the DCIM system are all patent and owned by Gerchamp.

What industries and use cases can a modular data center be used for?

Well beyond AI, modular blocks serve any workload that needs fast, dense, resilient compute close to power or users: AI/ML training and inference, HPC and scientific simulation, financial low-latency and risk workloads, oil & gas media rendering, healthcare and genomics, telecom and 5G edge (MEC), enterprise private cloud, sovereign and government compute, and energy or industrial sites — including behind-the-meter and stranded-power locations with wated natural gas.

How to choose between the 500kW all-in-one unit and the 3.5MW kit modular data center?

They are two distinct product lines that share one engineering philosophy but run on separate architectures. The 500kW All-in-One is a factory-integrated, standardized unit that ships ready to connect, it is the faster path for rapid deployments; you can add units to grow toward MW-class capacity as demand proves out. The 3.5MW Kit is configured to your site and workload, modular power and cooling tailored to your load profile, rack-level density tailored per aisle, and site-specific utility interface, redundancy, and code compliance. Both are powered-and-cooled shells with reserved positions for your chosen GPU/accelerator racks, so you bring the compute.

At a glance: 500kW = fast, standardized, turnkey; 3.5MW = large, configurable, site-assembled.