Data Center

Nickel-Zinc Battery Solution

What is a Nickel Zinc Battery?

Nickel-zinc (NiZn) batteries are intrinsically safe UPS backup batteries for AI data centers, offering a proven alternative to lead-acid and lithium systems.

The chemistry combines nickel and zinc electrodes with low internal resistance, enabling high-power delivery, while the water-based, non-flammable electrolyte means the battery produces no thermal runaway.

For backup windows of up to 15 minutes, Gerchamp Nickel-Zinc batteries deliver reliable 10C high-rate discharge with a substantially lower environmental footprint — and without the fire-protection measures that lithium-based systems require.

Nickel-Zinc Battery Technology

Which battery technology is best for data center UPS backup power: Nickel-Zinc, VRLA, or Lithium-Ion?

Data center UPS battery selection requires balancing high-power performance, thermal safety, and space constraints. Nickel-zinc (NiZn) technology is particularly suited to short-duration, high-power backup, offering a compact alternative to valve-regulated lead-acid (VRLA) batteries and a different safety profile from lithium-ion chemistry.

FeatureNickel-Zinc (NiZn)Lead-acid (VRLA)Lithium-ion (Li-ion)
Typical Lifespan10-15 years3-5 years8-10 years
Size and WeightCompact and LightweightBulky and HeavyCompact and Lightweight
Discharge RateUp to 10CTypically low; model-dependent1C-10C; technology-dependent
SafetyNo thermal runaway; aqueous electrolyteStable; hydrogen ventilation requiredChemistry-dependent; LFP safer than NMC/NCA
UPS Backup DurationMinutesMinutesMinutes
MaintenanceMaintenance-free; BMS monitoringPeriodic inspection; BMS monitoringLow; Built-in BMS monitoring
Environmental ImpactNo lead or cadmium; recyclable nickel and zinc materialsContains lead and sulfuric acid; established recycling infrastructureRecycling processes recover valuable metals; environmental impact depends on chemistry and lifecycle
*For more details read https://www.gerchamp.com/en-US/blog/nickel-zinc-battery-everything-you-need-to-know-and-faq

Safety Tests of Nickel-Zinc Batteries

Nickel-zinc runs on a water-based electrolyte —it cannot catch fire. The 8XNFG90 passed extreme abuse tests without fire or explosion, and achieved UL 9540A certification. Click any test to watch the footage:

For your facility

  • No fire suppression zone, no gas detection, no battery spacing rules
  • No toxic gas release under abnormal conditions
  • Non-hazardous dry battery — no transport restrictions
  • A much easier approval process with local authorities

Leak-proof by design

  • Liquid-absorption separator — electrolyte is held in place, no leakage
  • Four-layer sealing structure at terminals and case
  • Controlled pressure-release mechanism for safe pressure regulation
  • Multi-layer safety design to maintain battery integrity through service life

Frequently Asked Questions

  • Why choose nickel-zinc batteries for data center UPS applications?

    Nickel-zinc (NiZn) batteries combine high-power discharge capability with a compact design for short-duration UPS backup. They are an option for data centers evaluating battery safety, space utilization and maintenance requirements alongside backup performance.

  • Can nickel-zinc batteries replace VRLA batteries in an existing installation?

    Yes, Gerchamp's nickel-zinc batteries are compatible with mainstream UPS and can directly replace the existing VRLA batteries. Gerchamp offers both rack-installation solution with 8XNFG90 NiZn batteries and GZC-9038S NiZn cabinets.

  • How much backup runtime can your nickel-zinc battery solution provide?

    The short answer is 5-15 minutes. Backup runtime depends on the supported load, battery configuration and operating conditions. We size the solution around your required UPS power and runtime, including the capacity margin needed as batteries age.

  • What safety advantages do nickel-zinc batteries offer?

    Nickel-zinc chemistry is designed to avoid thermal runaway, helping reduce a key battery safety concern in critical facilities. Safe deployment still requires appropriate electrical protection, installation practices and compliance with site requirements.

  • What is included in a nickel-zinc battery cabinet solution?

    The GZC-9038S NiZn battery cabinet combines Gerchamp's 90Ah nickel-zinc batteries - 8XNFG90, battery monitoring systems (BMS) and electrical protection in one coordinated system. This simplifies specification and integration while providing centralized visibility into battery operating conditions.

  • How does the BMS help monitor battery health?

    The BMS monitors voltage, temperature, internal resistance and charge/discharge current, alongside state-of-charge (SOC) and state-of-health (SOH) assessment. These insights help operators identify abnormal conditions and plan targeted inspection or maintenance.

  • What safety advantages do Gerchamp's nickel-zinc batteries offer?

    Our nickel-zinc batteries have undergone extreme abuse testing, including axe chopping, drilling, heavy crushing and fire exposure, with no reported fire or explosion under the tested conditions. They have also passed UL 9540A thermal runaway fire propagation testing, providing additional safety assurance for mission-critical data center applications.

  • Can nickel-zinc batteries be used in high-performance applications?

    Yes. Our high-rate nickel-zinc batteries support discharge rates of up to 10C, delivering high power for demanding, short-duration UPS backup. Low internal resistance helps minimize voltage drop and heat generation under heavy loads, supporting stable power delivery during utility interruptions and generator startup.