For your facility
- No fire suppression zone, no gas detection, no battery spacing rules
- No toxic gas release under abnormal conditions
- Non-hazardous dry battery — no transport restrictions
- A much easier approval process with local authorities
Nickel-zinc (NiZn) batteries are intrinsically safe UPS backup batteries for AI data centers, offering a proven alternative to lead-acid and lithium systems.
The chemistry combines nickel and zinc electrodes with low internal resistance, enabling high-power delivery, while the water-based, non-flammable electrolyte means the battery produces no thermal runaway.
For backup windows of up to 15 minutes, Gerchamp Nickel-Zinc batteries deliver reliable 10C high-rate discharge with a substantially lower environmental footprint — and without the fire-protection measures that lithium-based systems require.

Data center UPS battery selection requires balancing high-power performance, thermal safety, and space constraints. Nickel-zinc (NiZn) technology is particularly suited to short-duration, high-power backup, offering a compact alternative to valve-regulated lead-acid (VRLA) batteries and a different safety profile from lithium-ion chemistry.
| Feature | Nickel-Zinc (NiZn) | Lead-acid (VRLA) | Lithium-ion (Li-ion) |
|---|---|---|---|
| Typical Lifespan | 10-15 years | 3-5 years | 8-10 years |
| Size and Weight | Compact and Lightweight | Bulky and Heavy | Compact and Lightweight |
| Discharge Rate | Up to 10C | Typically low; model-dependent | 1C-10C; technology-dependent |
| Safety | No thermal runaway; aqueous electrolyte | Stable; hydrogen ventilation required | Chemistry-dependent; LFP safer than NMC/NCA |
| UPS Backup Duration | Minutes | Minutes | Minutes |
| Maintenance | Maintenance-free; BMS monitoring | Periodic inspection; BMS monitoring | Low; Built-in BMS monitoring |
| Environmental Impact | No lead or cadmium; recyclable nickel and zinc materials | Contains lead and sulfuric acid; established recycling infrastructure | Recycling processes recover valuable metals; environmental impact depends on chemistry and lifecycle |
Nickel-zinc runs on a water-based electrolyte —it cannot catch fire. The 8XNFG90 passed extreme abuse tests without fire or explosion, and achieved UL 9540A certification. Click any test to watch the footage:
NO FIRE · NO EXPLOSION
NO FIRE · NO EXPLOSION
NO FIRE · NO EXPLOSION
Nickel-zinc (NiZn) batteries combine high-power discharge capability with a compact design for short-duration UPS backup. They are an option for data centers evaluating battery safety, space utilization and maintenance requirements alongside backup performance.
Yes, Gerchamp's nickel-zinc batteries are compatible with mainstream UPS and can directly replace the existing VRLA batteries. Gerchamp offers both rack-installation solution with 8XNFG90 NiZn batteries and GZC-9038S NiZn cabinets.
The short answer is 5-15 minutes. Backup runtime depends on the supported load, battery configuration and operating conditions. We size the solution around your required UPS power and runtime, including the capacity margin needed as batteries age.
Nickel-zinc chemistry is designed to avoid thermal runaway, helping reduce a key battery safety concern in critical facilities. Safe deployment still requires appropriate electrical protection, installation practices and compliance with site requirements.
The GZC-9038S NiZn battery cabinet combines Gerchamp's 90Ah nickel-zinc batteries - 8XNFG90, battery monitoring systems (BMS) and electrical protection in one coordinated system. This simplifies specification and integration while providing centralized visibility into battery operating conditions.
The BMS monitors voltage, temperature, internal resistance and charge/discharge current, alongside state-of-charge (SOC) and state-of-health (SOH) assessment. These insights help operators identify abnormal conditions and plan targeted inspection or maintenance.
Our nickel-zinc batteries have undergone extreme abuse testing, including axe chopping, drilling, heavy crushing and fire exposure, with no reported fire or explosion under the tested conditions. They have also passed UL 9540A thermal runaway fire propagation testing, providing additional safety assurance for mission-critical data center applications.
Yes. Our high-rate nickel-zinc batteries support discharge rates of up to 10C, delivering high power for demanding, short-duration UPS backup. Low internal resistance helps minimize voltage drop and heat generation under heavy loads, supporting stable power delivery during utility interruptions and generator startup.

Have a question or want to learn more? Send us a message.
Pick the cookies you're comfortable with. Strictly necessary cookies are always on because the site can't function without them. Privacy Policy
Required for core features like security, network management, language and theme. They never store tracking information.
Help us understand which pages are useful with anonymous, aggregated usage statistics.
Used to measure campaigns and show you more relevant content. These set advertising cookies.