# Liquid Cooling Solutions for Data Centers | Gerchamp

Home

Solutions

Liquid Cooling Solutions

![Hero Image](https://www.gerchamp.com/media/page-assets/uploads/2026/07/5ef36329-8086-4b7a-a956-fc6bf07ee185.webp)

Liquid Cooling Solutions

Data Center

Overview

Solution Overview

Driven by the rapid growth of artificial intelligence (AI), cloud services, and high-density computing (HPC) data centers, traditional air cooling systems are reaching their physical limits.  

Rack power density has increased from the traditional 6kW to 100–200kW per rack for AI clusters, while air-cooled system is limited to 40–50kW per rack. To address the growing thermal challenges, liquid cooling has become the key solution for next-generation data centers, delivering significantly higher heat dissipation efficiency and enabling PUE levels as low as 1.05 to 1.1. This transition also helps reduce power consumption, improve chip reliability, and support sustainability goals for data centres.

Gerchamp provides a comprehensive liquid cooling portfolio including **in-row/in-rack L2L coolant distribution units (CDU)**, **L2A side car for NVIDIA GB300/Rubin NVL72**, **prefabricated liquid cooling containers (DLCC)**, **immersion cooling solutions**, and maintenance equipment for new data center, AI data center, and brownfield retrofit projects. Our solutions are aligned with the global shift toward high-density, energy-efficient, and rapidly deployable infrastructure, supporting current mainstream deployments, scalable expansion, and future ultra-high-density computing environments.

Key Advantages

Why Choose Gerchamp Bluearth Liquid Cooling Solution for Data Centres

High-Density Cooling for AI and HPC Workloads

Support high-density racks from 150kW to 2700 kW with direct liquid cooling technologies for AI servers, HPC systems, and advanced computing applications.

Energy-Effcient with low PUE

Achieve PUE as low as 1.05, supporting high-efficiency data center requirements in markets including the United States, Europe, Singapore, and Malaysia.

Flexible and Rapid Deployment

Modular design including in-rack, in-row, liquid-to-liquid (L2L), liquid-to-air (L2A) and container solutions, enable fast implementation and adaptable expansion across diverse data center architectures.

### Related Content

#### Related Products

- [150kW/4U](https://www.gerchamp.com/en-US/products/150kw-4u-2-2-2) ([Agent MD](https://www.gerchamp.com/en-US/products/150kw-4u-2-2-2/raw.md)) - The 150 kW 4U CDU is a compact liquid cooling core unit installed in a standard 19-inch server rack, with a height of 4U. The 4U CDU is an optimal solution for addressing the heat dissipation bottlene
- [680kW/48U](https://www.gerchamp.com/en-US/products/680kw-48u-2) ([Agent MD](https://www.gerchamp.com/en-US/products/680kw-48u-2/raw.md)) - The 680 kW CDU is a liquid cooling unit that removes heat generated by equipment through the secondary-side heat exchange via a plate heat exchanger, and transfers the heat away through the primary-si
- [850kW](https://www.gerchamp.com/en-US/products/850kw-2-2) ([Agent MD](https://www.gerchamp.com/en-US/products/850kw-2-2/raw.md)) - Direct Liquid Cooling Container
The 850 kW system integrates secondary-side heat sources, CDU, and primary-side dry cooler within a standard 12 m container, forming a complete cooling system. Users ca


Related Products

### Related Content

#### Related Products

- [150kW/4U](https://www.gerchamp.com/en-US/products/150kw-4u-2-2-2) ([Agent MD](https://www.gerchamp.com/en-US/products/150kw-4u-2-2-2/raw.md)) - The 150 kW 4U CDU is a compact liquid cooling core unit installed in a standard 19-inch server rack, with a height of 4U. The 4U CDU is an optimal solution for addressing the heat dissipation bottlene
- [680kW/48U](https://www.gerchamp.com/en-US/products/680kw-48u-2) ([Agent MD](https://www.gerchamp.com/en-US/products/680kw-48u-2/raw.md)) - The 680 kW CDU is a liquid cooling unit that removes heat generated by equipment through the secondary-side heat exchange via a plate heat exchanger, and transfers the heat away through the primary-si
- [850kW](https://www.gerchamp.com/en-US/products/850kw-2-2) ([Agent MD](https://www.gerchamp.com/en-US/products/850kw-2-2/raw.md)) - Direct Liquid Cooling Container
The 850 kW system integrates secondary-side heat sources, CDU, and primary-side dry cooler within a standard 12 m container, forming a complete cooling system. Users ca

---

**Navigation**

[Home](https://www.gerchamp.com/en-US/) ([MD](https://www.gerchamp.com/en-US/raw.md)) | [Products](https://www.gerchamp.com/en-US/products/) ([MD](https://www.gerchamp.com/en-US/products/raw.md)) | [Solutions](https://www.gerchamp.com/en-US/solutions/) ([MD](https://www.gerchamp.com/en-US/solutions/raw.md)) | [Blog](https://www.gerchamp.com/en-US/blog/) ([MD](https://www.gerchamp.com/en-US/blog/raw.md)) | [About](https://www.gerchamp.com/en-US/about/) ([MD](https://www.gerchamp.com/en-US/about/raw.md)) | [Downloads](https://www.gerchamp.com/en-US/downloads/) ([MD](https://www.gerchamp.com/en-US/downloads/raw.md)) | [Contact](https://www.gerchamp.com/en-US/contact/) ([MD](https://www.gerchamp.com/en-US/contact/raw.md))