# CDU3680 L2L 680kW

Home

Products

CDU3680 L2L 680kW

![Product image](https://www.gerchamp.com/media/page-assets/uploads/2026/05/2e1ccd73-9f0e-4834-8722-e56ab55d36b2.webp)

CDU3680 L2L 680kW

The CDU3680 L2L 680kW is a liquid cooling unit that removes heat generated by equipment through the secondary-side heat exchange via a plate heat exchanger, and transfers the heat away through the primary-side chilled water loop.

Key Features

| Technical Parameter | Value / Details |
| --- | --- |
| Pump Redundancy | Adopts an N+1 pump configuration with cyclic switchover, ensuring continuous operation in case of single pump failure. |
| High Cooling Capacity In a Compact Footprint | Features a highly integrated piping design, with a footprintof only 1200 x 600 mm （LxW）, and is capable of removing up to 680 kW of heat. |
| Easy Maintenance Access | The electrical control cabinet adopts a tiltable structure. During maintenance, such as removing filter elements orreplacing pumps, the cabinet can be lifted via hydraulic supports, providing sufficient operating space. |
| Flexible Movement and Handling | Equipped with four heavy-duty casters at the base. The bottom structure allows for forklift handling for easy loading, and also enables flexible movement on the floor for convenient repositioning. |

Technical Parameters

Product Specifications

Complete technical data for the 680kW/48U L2L In-Row CDU.

| Parameter | Result |
|---|---|
| **TECHNICAL PARAMETERS: 680KW / 48U / L2L CDU** | - |
| Technical parameters | 680kW / 48U / L2L CDU |
| Rated cooling capacity | 680 kW @ 4.0°C ATD |
| Maximum flow rate – single pump operation | 700L/min, external pressure difference 2.0bar |
| Maximum flow rate – dual pump operation for N+ redundancy | 1050L/min, external pressure difference 3.4bar |
| Secondary coolant type | Pure Water or PG25 |
| Pump redundancy | Single pump (N) / dual pump (N+N) / dual pump switchover |
| Primary pressure drop | 0.8 bar (PG25) under typical conditions (650 L/min) |
| Secondary coolant temperature range | 10–55°C, with dew point control standard |
| Maximum power consumption | 4.5 kW (Single Pump) 7.3 kW (Dual Pump) |
| Dimensions (H × W × D) and weight | 1900 × 600 × 1050 mm, 550 kg |
| Noise level at 3m (10ft) | < 54 dBA |
| Power supply (Europe, Asia and Taiwan) | 3P 380-480 V 50/60 Hz |
| Dual power supply (ATS) | Optional features |
| Primary connections | Top or bottom, 2½-inch sanitary flange |
| Secondary connections | Top or bottom, 2½-inch sanitary flange |
| Secondary filtration | Optional 50um/20um |
| Communication | RS485 RTU modbus, TCP/IP SNMP |

Scroll to view all parameters

### Related Content

#### Related Products

- [Y850 DLCC 850kW](https://www.gerchamp.com/en-US/products/direct-liquid-cooling-container-850kW) ([Agent MD](https://www.gerchamp.com/en-US/products/direct-liquid-cooling-container-850kW/raw.md)) - Gerchamp Bluearth 850 kW Direct Liquid Cooling Container (DLCC) integrates secondary-side heat sources, CDU, and primary-side dry cooler within a standard 12 m container, forming a complete cooling system. Users ca

#### Related Solutions

- [Finance & Banking](https://www.gerchamp.com/en-US/solutions/battery-management-system-solutions-in-public-utilities) ([Agent MD](https://www.gerchamp.com/en-US/solutions/battery-management-system-solutions-in-public-utilities/raw.md)) - In the financial sector, the stability of power supply for core infrastructure is a non-negotiable baseline.
- [Telecommunication](https://www.gerchamp.com/en-US/solutions/battery-management-system-solutions-in-telecommunication) ([Agent MD](https://www.gerchamp.com/en-US/solutions/battery-management-system-solutions-in-telecommunication/raw.md)) - In the telecommunications industry, the rapid advancement of 5G network construction.
- [Data Center](https://www.gerchamp.com/en-US/solutions/ups-battery-management-system) ([Agent MD](https://www.gerchamp.com/en-US/solutions/ups-battery-management-system/raw.md)) - Modern data centers handle massive volumes of enterprise and personal data for storage.
- [Liquid Cooling Solutions](https://www.gerchamp.com/en-US/solutions/liquid-cooling-solutions-for-data-centers) ([Agent MD](https://www.gerchamp.com/en-US/solutions/liquid-cooling-solutions-for-data-centers/raw.md)) - Discover liquid cooling infrastructure including Coolant Distribution Units (CDU) and Direct Liquid Cooling Cabinets (DLCC) for AI, HPC and high-density data centers. Improve thermal efficiency, scalability and reliable cooling performance.

#### Related Documents & Downloads

- [CDU3680 L2L 680kW](/media/library/2026/07/74b3131b-ecd3-47e2-bfb7-93c1dbe54194.pdf) - Gerchamp Bluearth Liquid Cooling Series, Liquid-to-Liquid In-Row Cooling Distribution Unit 680kW


Related Contents

---

**Navigation**

[Home](https://www.gerchamp.com/en-US/) ([MD](https://www.gerchamp.com/en-US/raw.md)) | [Products](https://www.gerchamp.com/en-US/products/) ([MD](https://www.gerchamp.com/en-US/products/raw.md)) | [Solutions](https://www.gerchamp.com/en-US/solutions/) ([MD](https://www.gerchamp.com/en-US/solutions/raw.md)) | [Blog](https://www.gerchamp.com/en-US/blog/) ([MD](https://www.gerchamp.com/en-US/blog/raw.md)) | [About](https://www.gerchamp.com/en-US/about/) ([MD](https://www.gerchamp.com/en-US/about/raw.md)) | [Downloads](https://www.gerchamp.com/en-US/downloads/) ([MD](https://www.gerchamp.com/en-US/downloads/raw.md)) | [Contact](https://www.gerchamp.com/en-US/contact/) ([MD](https://www.gerchamp.com/en-US/contact/raw.md))