title: "GZC-9038S Nickel-Zinc Battery Cabinet"
description: "Explore the GZC-9038S nickel-zinc battery cabinet for safe 10C UPS backup in data centres, telecoms, rail and industrial systems."
image: "https://www.gerchamp.com/media/i/2df649c0-2314-4746-bd0e-7901adab7c2c/gzc-9038s-nickel-zinc-battery-cabinet-gerchamp-nickel-zinc-cabinet-gzc-9038s.webp"
---

# GZC-9038S Nickel-Zinc Battery Cabinet

Home

Products

GZC-9038S Nickel-Zinc Battery Cabinet

![Product image](https://www.gerchamp.com/media/i/2df649c0-2314-4746-bd0e-7901adab7c2c/gzc-9038s-nickel-zinc-battery-cabinet-gerchamp-nickel-zinc-cabinet-gzc-9038s.webp)

GZC-9038S

The **GZC-9038S is a next-generation nickel-zinc battery cabinet** designed for critical backup power. It integrates Gerchamp’s intelligent BMS with the 8XNFG90 nickel-zinc battery, delivering 10C high-rate discharge, intrinsic safety, and zero thermal runaway risk.

As a compact and safer alternative to traditional lead-acid battery cabinets and racks, this nickel-zinc battery cabinet is ideal for data centres, AI computing rooms, industrial backup systems, rail transport, and telecoms base stations.

Key advantages of the GZC-9038S nickel-zinc battery cabinet

| Technical Parameter | Value / Details |
| --- | --- |
| **Intrinsic Safety** | Aqueous electrolyte with no thermal runaway, fire, or explosion risk; no open circuit during discharge, ensuring reliable series-connected battery strings. |
| **10C Discharge Rate** | Supports 0.5C–10C discharge, balancing capacity and power to suit different applications. |
| **Wide Temperature Range** | Stable, efficient performance from −20°C to 55°C, breaking traditional battery temperature limits. |
| **Rapid Deployment** | Compatible with mainstream MW-class UPS inverters, directly replacing existing lead-acid battery cabinets with no power distribution system modifications. |
| **Eco-Friendly** | >90% recyclable and made from non-polluting materials, supporting clean energy and cutting carbon footprint. |
| **Smaller and Lighter** | Higher power density with 1/2 size reduction and 2/3 weight reduction of lead-acid batteries at same capacity. |

Technical Parameters

Product Specifications

Detailed specifications of the GZC-9038S nickel-zinc battery cabinet

| **Model** | **GZC-9038S** | **GZC-9037S** | **GZC-9036S** |
| --- | --- | --- | --- |
| Battery configuration | 38S | 37S | 36S |
| Cabinet energy | 45kWh | 44kWh | 43kWh |
| Rated voltage | 501VDC | 488VDC | 475VDC |
| Charging voltage | Float charge 562.4VDC, equalization charge 577.6VDC | Float charge 547.6VDC, equalization charge 562.4VDC | Float charge 532.8VDC, equalization charge 547.2VDC |

| Item | Specification |
| --- | --- |
| Cell nominal capacity | 90Ah (discharge at 90A to 10.4V, 25℃) |
| Cell nominal energy | 1.188kWh |
| Battery option | Nickel-zinc battery - 8XNFG90 |
| Charging current | 27A~90A |
| Standard charging current | 45A |
| Maximum discharge current | 900A |
| Charging time | 3-5 hours |
| Application | Used for backup power scenarios of less than 15 minutes |

| **System BMS Function** |  |
| --- | --- |
| Monitoring | Monitor and analysis battery voltage, internal resistance, temperature, charge/discharge current, equalization voltage, float voltage, etc. |
| State estimation | SOC, SOH |
| Self-test | Automatic test cycle can be set without manual intervention |
| Alarm | Support alarm management; when any value exceeds the limit, an alarm is automatically triggered, local indicator lights up, buzzer sounds, alarm register is set, and dry contact is activated |
| Data record | Support historical data recording / event alarm recording |
| Data communication | 1 Ethernet port output<br>Communication protocols: MODBUS/RTU, MODBUS/TCP, SNMP |
| Built-in WEB | Support WEB remote real-time data viewing, function control, and parameter configuration |

| **Safety** |  |
| --- | --- |
| Certification | UL 9540A, EU2023-1542, RoHS, UL 94 V-0 |
| Circuit breaker protection | In case of overload fault, the circuit breaker trips |
| Fuse protection | In case of short circuit fault, the fuse blows |
| Operating temperature range | Discharge: `-20℃~+55℃`  Charge: `0℃~+40℃` |
| Storage temperature range | -20℃~+55℃ |
| Storage period | After storage exceeding 3 months at 25℃, the battery requires recharging |
| Humidity range | 0~85%, non-condensing |
| Cooling method | Air cooling |

| **Mechanical** |  |
| --- | --- |
| Dimension | 530(W) x 1000(D) x 2100(H) mm |
| Weight | 1100kg |

### Related Content

#### Related Products

- [8XNFG90](https://www.gerchamp.com/en-GB/products/8xnfg90) ([Agent MD](https://www.gerchamp.com/en-GB/products/8xnfg90/raw.md)) - Explore the 8XNFG90, Gerchamp's new-generation 10C nickel-zinc battery. The 8XNFG90 NiZn batteries are inherently safe by design.

#### Related Solutions

- [Nickel-Zinc Battery Solution](https://www.gerchamp.com/en-GB/solutions/nickel-zinc-battery-solution) ([Agent MD](https://www.gerchamp.com/en-GB/solutions/nickel-zinc-battery-solution/raw.md)) - Zero thermal runaway for safer backup power solutions. Nickel-Zinc Battery & Cabinet: smaller, lighter, greener – a reliable and sustainable choice.
- [Data Center](https://www.gerchamp.com/en-GB/solutions/ups-battery-management-system) ([Agent MD](https://www.gerchamp.com/en-GB/solutions/ups-battery-management-system/raw.md)) - Modern data centres handle massive volumes of enterprise and personal data for storage.
- [Modular & Prefabricated Data Centre | 500kW to 3.5MW for Fast Deployment](https://www.gerchamp.com/en-GB/solutions/modular-prefabricated-data-centre-500kw-to-3-5mw-for-fast-deployment) ([Agent MD](https://www.gerchamp.com/en-GB/solutions/modular-prefabricated-data-centre-500kw-to-3-5mw-for-fast-deployment/raw.md)) - Liquid-cooled modular data centres that expand block by block. Deploy 500kW all-in-one modular AIDC or 3.5MW kit modular AIDC for AI training and inference in…

#### Related Documents & Downloads

- [Gerchamp-GZC-9038S Nickel-Zinc-Battery Cabinet-leaflets-A0.pdf](/media/d/gerchamp-gzc-9038s-nickel-zinc-battery-cabinet-leaflets-a0.pdf) - 


Related Content
## Related Solutions & Products

- [Nickel-Zinc Battery Solution](https://www.gerchamp.com/en-GB/solutions/nickel-zinc-battery-solution) ([Agent MD](https://www.gerchamp.com/en-GB/solutions/nickel-zinc-battery-solution/raw.md)) - Zero thermal runaway for safer backup power solutions. Nickel-Zinc Battery & Cabinet: smaller, lighter, greener – a reliable and sustainable choice.
- [Gerchamp-GZC-9038S Nickel-Zinc-Battery Cabinet-leaflets-A0.pdf](https://www.gerchamp.com/media/d/gerchamp-gzc-9038s-nickel-zinc-battery-cabinet-leaflets-a0.pdf)
- [Data Center](https://www.gerchamp.com/en-GB/solutions/ups-battery-management-system) ([Agent MD](https://www.gerchamp.com/en-GB/solutions/ups-battery-management-system/raw.md)) - Modern data centres handle massive volumes of enterprise and personal data for storage.
- [Modular & Prefabricated Data Centre | 500kW to 3.5MW for Fast Deployment](https://www.gerchamp.com/en-GB/solutions/modular-prefabricated-data-centre-500kw-to-3-5mw-for-fast-deployment) ([Agent MD](https://www.gerchamp.com/en-GB/solutions/modular-prefabricated-data-centre-500kw-to-3-5mw-for-fast-deployment/raw.md)) - Liquid-cooled modular data centres that expand block by block. Deploy 500kW all-in-one modular AIDC or 3.5MW kit modular AIDC for AI training and inference in…
- [8XNFG90](https://www.gerchamp.com/en-GB/products/8xnfg90) ([Agent MD](https://www.gerchamp.com/en-GB/products/8xnfg90/raw.md)) - Explore the 8XNFG90, Gerchamp's new-generation 10C nickel-zinc battery. The 8XNFG90 NiZn batteries are inherently safe by design.


---

**Navigation**

[Home](https://www.gerchamp.com/en-GB/) ([MD](https://www.gerchamp.com/en-GB/raw.md)) | [Products](https://www.gerchamp.com/en-GB/products) ([MD](https://www.gerchamp.com/en-GB/products/raw.md)) | [Solutions](https://www.gerchamp.com/en-GB/solutions) ([MD](https://www.gerchamp.com/en-GB/solutions/raw.md)) | [Blog](https://www.gerchamp.com/en-GB/blog) ([MD](https://www.gerchamp.com/en-GB/blog/raw.md)) | [About](https://www.gerchamp.com/en-GB/about) ([MD](https://www.gerchamp.com/en-GB/about/raw.md)) | [Downloads](https://www.gerchamp.com/en-GB/downloads) ([MD](https://www.gerchamp.com/en-GB/downloads/raw.md)) | [Contact](https://www.gerchamp.com/en-GB/contact) ([MD](https://www.gerchamp.com/en-GB/contact/raw.md))

```json
[
  {
    "@context": "https://schema.org",
    "@type": "BreadcrumbList",
    "itemListElement": [
      {
        "@type": "ListItem",
        "item": "https://www.gerchamp.com/en-GB/",
        "name": "Home",
        "position": 1
      },
      {
        "@type": "ListItem",
        "item": "https://www.gerchamp.com/en-GB/products",
        "name": "Products",
        "position": 2
      },
      {
        "@type": "ListItem",
        "item": "https://www.gerchamp.com/en-GB/products/gzc-9038s-nickel-zinc-battery-cabinet",
        "name": "GZC-9038S Nickel-Zinc Battery Cabinet",
        "position": 3
      }
    ]
  },
  {
    "@context": "https://schema.org",
    "@id": "https://www.gerchamp.com/en-GB/products/gzc-9038s-nickel-zinc-battery-cabinet#product",
    "@type": "Product",
    "brand": {
      "@type": "Brand",
      "name": "Gerchamp"
    },
    "category": "Products",
    "description": "Explore the GZC-9038S nickel-zinc battery cabinet for safe 10C UPS backup in data centres, telecoms, rail and industrial systems.",
    "image": "https://www.gerchamp.com/media/i/2df649c0-2314-4746-bd0e-7901adab7c2c/gzc-9038s-nickel-zinc-battery-cabinet-gerchamp-nickel-zinc-cabinet-gzc-9038s.webp",
    "inLanguage": "en-GB",
    "manufacturer": {
      "@id": "https://www.gerchamp.com/#organization",
      "@type": "Organization",
      "name": "Gerchamp",
      "url": "https://www.gerchamp.com"
    },
    "mpn": "GZC-9038S",
    "name": "GZC-9038S Nickel-Zinc Battery Cabinet",
    "sku": "GZC-9038S",
    "url": "https://www.gerchamp.com/en-GB/products/gzc-9038s-nickel-zinc-battery-cabinet"
  }
]
```